Skip to content

Daikin Applied

Principal Engineer: Electrical Power Pods

Remote (United States) · posted Nov 28, 2026 · listed from another job board

Source: Himalayas

Sign up to apply

  • Job alerts

    Get new roles like this daily or weekly, in the app or by email.

  • Easy Apply

    Apply to jobs posted here with your saved profile.

  • AI match

    See how your profile matches each job, and why.

Create a free account
Share this job

At a glance

Salary
$146,900 – $246,200 a year
Workplace
Remote
Location
Remote (United States)
Hiring in
US (as named in the listing)
Region
North america
Time zones
UTC−10 to UTC−5
Employment type
Full time
Seniority
Mid senior
Skills
AI
Posted
2026-11-28

About the job

Join the world's largest HVAC company!

We are seeking a Principal Engineer: Electrical Power Pod to bring that systems perspective to Prefab AI Factories. You will lead the technical definition, development and design assurance of electrical power pods, carrying engineering decisions from requirements and equipment integration through factory testing and deployed performance. This role offers substantial technical ownership for an engineer with deep data center experience, hands-on AC and DC power expertise, and the judgment to resolve difficult multidisciplinary challenges. You will help determine how power infrastructure performs under demanding conditions. Your work will connect technical authority with physical outcomes, from design reviews and test results to dependable operation in Prefab AI Factories.

Location: Remote based

What you will lead:

  • Power-pod technical definition. Establish the design basis, equipment ratings, operating modes, redundancy, maintainability and measurable acceptance criteria.
  • Integrated AC and DC engineering. Lead single-line diagrams, equipment specifications, load schedules, power-conversion interfaces, protection, grounding, bonding and metering requirements.
  • Electrical performance and resilience. Evaluate power quality, transient response, load changes, transfer sequences, fault behavior and recovery. Translate operating scenarios into design and test requirements.
  • Design assurance. Define and review load-flow, short-circuit, protection-coordination and arc-flash studies, working with specialists where appropriate. Resolve findings and coordinate applicable safety and certification requirements.
  • Equipment and system interfaces. Integrate distribution equipment, power electronics, energy storage, controls and connected loads. Lead technical reviews and resolve gaps across engineering and supplier deliverables.
  • Validation and deployment readiness. Establish factory and site acceptance criteria, support integrated testing and commissioning, and lead the technical resolution of performance issues.
  • Product lifecycle and engineering quality. Develop reusable design practices, support manufacturing, qualify substitutions, investigate field failures and incorporate lessons into subsequent releases. Mentor engineers and provide clear direction on difficult technical decisions.
  • Power-pod technical definition. Establish the design basis, equipment ratings, operating modes, redundancy, maintainability and measurable acceptance criteria.
  • Integrated AC and DC engineering. Lead single-line diagrams, equipment specifications, load schedules, power-conversion interfaces, protection, grounding, bonding and metering requirements.

What you bring

  • Demonstrated experience designing and delivering data center electrical infrastructure, including critical power distribution, capacity planning, protection, redundancy and maintainability.
  • Deep knowledge of medium- and low-voltage electrical distribution and practical experience integrating transformers, switchgear, switchboards, circuit breakers, busway, variable frequency drives (VFDs), generators, uninterruptible power supply (UPS) systems, battery technologies, power converters and IT rack power distribution.
  • Hands-on DC power-system design or integration experience, including switching, protection, fault management, grounding or isolation strategies, and power-conversion interfaces.
  • Strong knowledge of grounding and bonding, including high-resistance grounding (HRG), metering and surge protection.
  • Technical ownership extending through equipment integration, factory acceptance testing and commissioning.
  • Deep understanding of data center availability requirements, concurrent maintenance, failure response and capacity expansion.
  • The ability to interpret electrical studies, assess design risks and make defensible decisions about real hardware.
  • Experience with EPLAN or comparable electrical engineering and drafting software.
  • Working knowledge of applicable electrical safety, certification and compliance requirements.
  • Strong written, verbal and presentation skills, with the ability to lead internal and customer-facing presentations and technical working sessions.
  • Self-motivation and sound judgment, with the ability to thrive in a fast-paced environment and make progress amid ambiguity.
  • An electrical engineering degree or equivalent relevant technical experience, supported by a record of technical leadership across disciplines.

Experience that will set you apart

  • Designing prefabricated or modular data center power solutions, including power pods, e-houses, packaged substations or integrated power-conversion and distribution systems.
  • Engineering DC distribution for critical facilities, high-power computing or comparable demanding applications.
  • Understanding and resolving competing thermal, mechanical, electrical, power security and resiliency requirements.
  • Designing electrical systems to meet th

More remote jobs at Daikin Applied

All 3 remote jobs at Daikin Applied

More jobs like this

Get matched to jobs like this

Free profile, Easy Apply on jobs posted here, and alerts for new roles.

Join free